INSTEK LCR-6020 CALIBRATION and INSTEK LCR-6020 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK LCR-6020 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   INSTEK LCR-6020   Description / Specification:    
INSTEK LCR-6020 20kHz LCR Meter

The Instek LCR-6020 20kHz LCR Meter has a 3.5-inch color LCD to simultaneously display setting criteria and measurement results, it increases two additional monitoring parameters. In other words, there are four parameters, primary/secondary and two monitoring, simultaneously shown on the screen that tremendously enhances the measurement efficiency. The enlarge display mode not only emphasizes the measurement results, but also provides PASS/FAIL judgment to facilitate a rapid and convenient test result.
Specifications.

Test Frequency: 10Hz to 20kHz (±0.01%) (4 digits resolution).
Output impedance: 30Ω / 50Ω / 100Ω selectable.
Basic Accuracy: 0.05% (Slow / Med), 0.1% (Fast).
Test Speed: FAST: 25ms / MED: 100ms / SLOW: 333ms.
Test Signal Levels.
  AC Voltage: 10.00mV to 2.00V (±10%), CV 10.00mV- to 2.00V (±6%).
  AC Current: 100.0μA to 20.00mA (±10%), CC 100.0μA to 20.00mA (±6%) (@2VMax).
  DCR: +2V, 0.066A (Max.), Output impedance fixed 30Ω.
DC Bias Internal: ±2.5V (0.5%+0.005V).
Display Range.
  R, X, |Z|: 0.00001Ω ~ 99.9999MΩ,
  G, B, |Y|: 0.01nS ~ 999.999S,
  L: 0.00001μH ~ 9999.99H,
  C: 0.00001pF ~ 9999.99mF,
  D: 0.00001 ~ 9.99999,
  Q: 0.00001 ~ 99999.9,
  θd: -179.999° ~ 179.999°,
  θr: -3.14159 ~ 3.14159,
  DCR: 0.00001Ω ~ 99.9999MΩ,
  Δ%: -99999% ~ 99999%.
Test Mode Combinations (16): Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your INSTEK LCR-6020 CALIBRATION and/or INSTEK LCR-6020 20kHz LCR Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: